FKRS-EU-introduction-image
FKRS-EU_img_35_Highlightsai.png

FKRS-EU with fusible link for 72 °C or 95 °C

CE-konform
CE compliant according to European regulations
ASi_LonMarkai.ai.link

With TROXNETCOM as an option

ATEX-certification

ATEX certification

Conforms to VDI 6022

FKRS-EU-introduction-image
FKRS-EU_img_35_Highlightsai.png
CE-konform
ASi_LonMarkai.ai.link
ATEX-certification

FKRS-EU            

Compact dimensions – ideal for restricted spaces

Small circular fire damper for shutting off air ducts between 2 fire compartments, available in 10 nominal sizes
■ Nominal sizes: 100 – 315 mm
■ Low differential pressure and sound power level
■ Optional as explosion-proof variant (ATEX)
■ Optional as air transfer damper with fusible link
■ Optional as air transfer damper
■ Optional with stainless steel casing or powder-coated casing for increased corrosion protection
■ Integration into MCE/BACS with TROXNETCOM
■ Universal installation options

Optional equipment and accessories
■ Electric actuator 24 V/230 V
■ Release temperature 72/95 °C

Useful additions
■ Duct smoke detectors

General information

Application
  • Fire dampers with CE marking and declaration of performance, for the isolation of duct penetrations between two fire compartments in the event of a fire
  • To prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments

Special characteristics
  • Declaration of Performance according to the European Construction Products Regulation
  • Classification up to EI 120 (ve, ho, i ↔ o) S according to DIN EN 13501-3
  • Certified mortar-based installation with reduced distances of 40 mm to load-bearing components or at least 10 mm between 2 fire dampers
  • Circumferential gap dimensions in the mortar-based installation up to 225 mm permitted
  • Installation also possible in walls and ceilings with slope
  • Complies with European product standard DIN EN 15650
  • Tested for fire resistance properties in accordance with EN 1366-2 (300 Pa and 500 Pa negative pressure)
  • Meets the hygienic requirements according to VDI 6022-1, VDI 3803-1, DIN 1946-4, DIN EN 16798-3 as well as Ö-Norm H 6020 and H 6021 and SWKI
  • Corrosion protection according to DIN EN 15650 in connection with DIN EN 60068-2-52
  • Closed blade leakage airflow to EN 1751, class 3
  • Casing air leakage to EN 1751, class C
  • Low differential pressure and sound power level
  • Any airflow direction
  • Integration into the MCE with TROXNETCOM
  • Integration into the MCE with the international standard fire damper system according to IEC 62026-2 with AS-interface is possible

Classification
  • Performance class up to EI 120 (ve, ho, i ↔ o) S according to DIN EN 13501-3

Nominal sizes
  • 100, 125, 150, 160, 180, 200, 224, 250, 280, 315
  • L: 400 mm

Variants
  • with fusible link
  • with spring return actuator
  • with spring return actuator for use in potentially explosive atmospheres
  • with spring return actuator with duct smoke detector RM-OM
  • with cover grille on both sides as air transfer damper (FD)
  • As an air transfer damper with spring return actuator, duct smoke detector and cover grille on both sides according to General construction technique permit Z-6.50-2516

For installation in Germany, please note: if a fire damper with only a mechanical shut-off element (fusible link) is to be used as an air transfer damper (FD), the local building regulations apply.
The use of such air transfer dampers (FD) is usually limited to pressure differential systems.

Parts and characteristics
  • Release temperature 72 °C or 95 °C (for use in warm air ventilation systems)
  • Single-handed operation
  • Installation orientations from 0° - 360
  • Explosion-proof constructions for zones 1, 2, 21, 22

Attachments
  • Limit switch for damper blade position indication
  • Spring return actuator with 24 V AC/DC or 230 V AC supply voltage
  • Spring return actuator for 24 – 230 V supply voltage, for use in potentially explosive atmospheres
  • Network module for integration in AS-i networks, MODBUS RTU and BACnet MS/TP (RS485)
  • Spring return actuator and pre-wired RM-O-M smoke detector with 230 V AC or 24 V DC supply voltage for use in air ducts
  • Spring return actuator and pre-wired RM-O-3-D smoke detector with 230 V AC or 24 V DC supply voltage for use as air transfer damper (MFD)
  • All attachments can also be retrofitted

Accessories
  • Installation block ER for dry mortarless installation in solid walls and ceilings
  • Installation kit TQ2 for dry mortarless installation in solid walls, in lightweight partition walls/compartment walls with metal support structure and cladding on both sides, in shaft walls with and without metal support structure, in timber stud walls, half-timbered construction and solid wood walls and in solid wood ceilings and wooden beam ceilings and wooden panel elements
  • Installation kit TS2 for dry mortarless installation of 2 FKRS-EU in solid wood ceilings (one installation opening as twin installation)
  • Installation kit WA2 for dry mortarless installation in solid walls as well as in single-sided shaft walls with and without metal stud framing

  • Installation kit WE2 for dry mortarless installation away from solid walls and ceilings as well as away from lightweight walls with metal stud frame cladding on both sides
  • Installation kit GL2 for installation in lightweight partition walls/fire walls with flexible ceiling joint and for dry mortarless installation in lightweight partition walls with metal stud framing on both sides during wall construction
  • Cover grille
  • Flexible connectors
  • Extension piece

Useful additions

  • Duct smoke detector RM-O-3-D
  • Duct smoke detector with airflow monitor RM-O-O-M

Construction features
  • Stable, circular casing suitable for push fitting into drilled cut holes without additional drilling and chiselling being required
  • Spigot connections with lip seal on both sides, suitable for ventilation ducts according to EN 1506 or EN 13180 plus non-standard but commercial nominal sizes 180, 224 and 280
  • Suitable for the connection of ducts, cover grilles or flexible connectors
  • The release mechanism is accessible and can be tested from the outside
  • One inspection access panel
  • Remote control with spring return actuator

Standards and guidelines
  • EU Construction Products Regulation
  • EN 15650 Ventilation for buildings – Fire dampers
  • DIN EN 1366-2 Fire resistance tests for service installations – Fire dampers
  • EN 13501-3 Fire classification of construction products and building elements
  • DIN EN 1751: Ventilation for buildings – Air terminal devices
  • 2006/42/EC – Machinery Directive
  • 2014/34/EU – ATEX Directive

Material and surfaces
Casing:

  • Galvanised sheet steel
  • Galvanised sheet steel, powder-coated RAL 7001
  • Stainless steel 1.4301

Damper blade:
  • Special insulation material
  • Special insulation material with impregnation
  • Replaceable damper blade (from NS 180 mm)

Other components:

  • Damper blade shaft made of galvanised steel or stainless steel
  • Elastomer seals

The design variants made of stainless steel or with powdercoated casings meet increased requirements for corrosion protection. Detailed resistance lists upon request.

Supply package

If attachments and accessories are factory-mounted on the fire dampers, they are already included in the order code. Depending on the installation situation, additional materials such as mortar, screws or mineral wool may be required for correct installation. Such materials are not usually included in the supply package (unless stated otherwise). Attachments and accessories have to be selected by people in charge of the building project. These people also have to select and provide any additionally required installation or fixing materials and make sure that the required classifications are met.

Maintenance
  • At the instigation of the owner of the ventilation system, the functional test of the fire damper must be carried out at least every six months, taking into account the basic maintenance measures in accordance with DIN EN 13306 in conjunction with DIN EN 31051. If two consecutive tests, one six months after the other, are successful, the next test can be conducted one year later.
  • A functional test involves closing the damper blade and opening it again; with a spring return actuator, this function can be done via a remote control
  • Fire dampers must be included in the regular cleaning schedule for the ventilation system.
  • For details on functional tests, maintenance and inspection refer to the operating and installation manual

Technical data
  • Nominal sizes: 100 to 315 mm
  • Casing length: 400 mm
  • Volume flow range: up to 770 l/s (2770 m³/h)
  • Differential pressure range: up to 1500 Pa
  • Temperature range: -20 - 50 °C *
  • Upstream velocity **:
    • Standard construction ≤ 8 m/s
    • Variant with spring return actuator ≤ 10 m/s
    • Variant with explosion-proof actuator ExMax/ RedMax-15-BF TR ≤ 10 m/s

* For FKRS-EU in Ex variant, see supplementary operating manual

** Data applies to uniform upstream and downstream conditions of the fire dampers

Correct use
  • The fire damper is used as an automatic shut-off device to prevent fire and smoke from spreading through the air duct
  • The fire damper is suitable for supply and extract air in ventilation and air conditioning systems
  • The fire damper may be used in areas with potentially explosive atmospheres if suitable special accessories are used and if the product bears the CE conformity marking according to Directive 2014/34/EU. Fire dampers for use in areas with potentially explosive atmospheres are marked for the zones for which they have been approved
  • Operation of fire dampers is allowed only in compliance with installation regulations and the technical data in the installation and operating manual
  • Modifying the fire damper or using spare parts that have not been approved by TROX is not permitted

Incorrect use:
  • Without specially approved attachments in areas with potentially explosive atmospheres
  • As a smoke control damper
  • Outdoors without sufficient protection against weather effects
  • In atmospheres where chemical reactions, whether planned or unplanned, may cause damage to the fire damper or lead to corrosion

For installation in Germany, please note:
  • Do not use in extract air systems in commercial kitchens
  • Use as an air transfer damper (MFD) only in accordance with General construction technique permit Z-6.50-2516
  • Use with a combined penetration seal requires projectrelated type-approval.
  • Installation in the fire protection block bulkhead only with project-related type approval
  • The use of air transfer dampers (FD) may require a building inspectorate licence. This must be checked and applied for by the client.
  • Flame-resistant, non-dripping building materials (elastomeric foams) must at least comply with fire rating class C - s2, d0 in accordance with the specifications of the German M-VV TB (since 2019/01) guideline. The current national building regulations apply.

Downloads

product information

certificates

operation manuals

production {"x-frame-options"=>"SAMEORIGIN", "x-xss-protection"=>"1; mode=block", "x-content-type-options"=>"nosniff", "x-download-options"=>"noopen", "x-permitted-cross-domain-policies"=>"none", "referrer-policy"=>"strict-origin-when-cross-origin", "strict-transport-security"=>"max-age=31536000; includeSubDomains", "content-type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request.
Tel.: +61 (02) 8923 2551

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +61 (02) 8923 2551

Contact

We are here for you

Please specify your message and type of request.
Tel.: +61 (02) 8923 2551

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +61 (02) 8923 2551