VAV terminal units

Product Finder

layer

TVR


  • Circular air terminal units for standard applications in supply air or extract air systems with variable volume flow rates
  • Suitable for the control of volume flow rate, room pressure or duct pressure
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • High control accuracy even with upstream bend (R = 1D)
  • Closed blade air leakage to EN 1751, up to class 4
  • Casing air leakage to EN 1751, class C

 

Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer CA (for Germany and Switzerland), CAH (for EMEA) CS or CF for the reduction of air-regenerated noise
  • Hot water heat exchanger WL and electric air heater EL for reheating the airflow

read more

layer

TFP

Series flow fan powersd terminals offer enhanced space comfort and flexibility In a wide variety of applications.

Considerable operating savings can be achieved through the recovery af waste heat,reduced central fan horsepower requirements and night setback operation.lROX Tennlnal Boxes Type ''TFP" take primary and induced air and mix the two thoroughly to provide a constant air supply to the oc­ cupied zone af the building.Totalflow to the diffuser Is kept substantially constant thus giving very good air distribution even with high turn down of the primary air volume.

A pressure independent controlof the primary VAV damper is accomplished by use af a differential pressure grid which gives accurate controlaf air flow even with a goo bend on the inlet spigot.Mixing between the primary airstr8am and the induced warm air from the ceiling void is by a forward curved blade centrifugal fan with direct drive motor.

TROX Series Fan Tenninal Boxes are eminently suitable for low temperature air applications.If the supply air tempera­ ture Is low,then the fan volume flow rate must be higher than the primary air volume flow rate to ensure suitable air temperature at the diffuser.The design af the type TFP ensures that at 100 % primary air,sulftclent Induced air Is mixed with the primary air so that the air discharged has a conventional cooling differential which will not cause draught problems In the space being conditioned.The primary air damper can also be fully shut,with 100 % recirculated or induced air.


read more

layer

TVM


 

VAV dual duct terminal units for dual duct systems with variable volume flows in buildings with demanding acoustic requirements

  • Individual temperature control for each room or zone
  • Highly effective integral attenuator
  • Electronic control components for various applications
  • Closed blade air leakage to EN 1751, up to class 4
  • Casing leakage to EN 1751, Class B

 

 

Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise

 

 

 


read more

layer

TVB

Trox VARYCONTROL terminal boxes type TVB is suitable for volume flow control of supply air in VAV systems. These are terminal boxes with circular inlet spigot and a larger, rectangular outlet section.
 
Terminal boxes are used in VAV systems with a high level of technical and acoustic requirements. Different versions allow appropriate selection of terminals to meet project-specific control requirements. The heating requirements in the outer zones of an air-conditioned building can be covered with an electric heater. The air diffusers can be connected directly to a multiple outlet box to save branch ducting and installation costs
 

read more

layer

TCP

The TCP VAV unit is typically used in systems that require perimeter heating in winter of supplementary cooling in certain occupied zones. It consists of two major components, a primary air damper and a secondary air induction indoor fan. A pressure independent control of the primary VAV damper is accomplished by using a differential pressure grid which provides an accurate control of air flow. Mixing between the primary air and the induced warm recirculated air from the ceiling void is achieved by means of a forward-curved centrifugal fan with a direct drive motor. For winter operations, the induction fan provides an economical way of utilizing the recycled heat generated by inner zone. The fan transfers the recycled heat from inner zone to the perimeter zone utilising the returned air from ceiling void or rooms. Cycling of the fan results in energy savings as activation is only required when required in a specific zone. Placement of the fan is critical to ensure the desired occupant comfort levels. Hot water coil or electric heater for secondary heating is available. All controllers or electrical components are factory fitted and VAV controller is factory calibrated.

read more

layer

TVL

Equipment features and characteristics
• TROX Vary Control VAV type ‘TVL’ volume flow control unit is suitable_
for variable or constant air volume control
• Multiple aerofoil blade
• Suitable for small or large supply or extract air volumes
• Electronic volume flow control
• Differential pressure range 20 Pa to 1000 Pa
• Electric or hot water coil heating facilities are available
• TVL units can be operated with any DDC, electronic or pneumatic VAV controller
• TVL units are suitable for an airflow ranging from 45 l/s to 10,100 l/s_
A typical airflow accuracy of ± 5% depending on the airflow rate and Type of controller used
• The unit is tested to:
- ISO 5220 for “Aerodynamic testing and rating of constant and variable dual or single units”

- ISO 3741 for “Determination of sound levels of noise sources – Precision methods for broad-band sources in reverberation rooms”

- The insulation material is tested to BS 470:Part 6 and 7 and is classified as Class ‘O’ under the British Building Regulations

read more

layer

TVR-Ex

Circular VAV terminal units for variable air volume systems, approved and certified for potentially explosive atmospheres (ATEX)

  • ATEX-compliant construction and parts

  • Approved for all gases, mists and vapours in zones 1 and 2, with electronic control additionally for dusts in zones 21 and 22

  • Suitable for the control of supply or extract air as well as for differential pressure control

  • Electronic or pneumatic control components

  • Closed blade air leakage to EN 1751, up to class 4

  • Casing air leakage to EN 1751, class C

 


Optional equipment and accessories

  • Spring return actuator

  • Auxiliary switch with adjustable switching points for capturing the end positions

 

read more

Please select your required product characteristics:
For the most diverse applications regarding standard volume flow rate ranges TVR

TVR

For the most diverse applications regarding standard volume flow rate ranges

read more

For dual duct systems TVM

TVM

For dual duct systems

read more

For the control of variable air volume flows in potentially explosive atmospheres (ATEX) TVR-Ex

TVR-Ex

For the control of variable air volume flows in potentially explosive atmospheres (ATEX)

read more

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Content-Security-Policy"=>"frame-ancestors 'self' https://api.scrivito.com https://punchoutcommerce.com https://www.trox.de https://trox-extern.com https://psp40.onventis.com https://psp22.onventis.com https://trox4u.troxgroup.com", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request.
Tel.: +61 (02) 8923 2551

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +61 (02) 8923 2551

Contact

We are here for you

Please specify your message and type of request.
Tel.: +61 (02) 8923 2551

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +61 (02) 8923 2551